Customization: | Available |
---|---|
Task: | Controller |
Signal: | Continuous |
Still deciding? Get samples of US$ 35/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Driver |
Insulation Resistance | 100Mohms or more when 500VDC is applied between the windings and the frame |
Dielectric Strength | Sufficient to withstand 0.5KVAC at 50Hz applied between the PG and power supply input terminal for 1 minute. |
Operating Ambient Temperature | 0~ +50 deg. C, nonfreezing |
Environment humidity | 85% maximum, non-condensing |
Conditions Atmosphere | No corrosive gases or dust |
Degree of Protection | - |
SRM-24 | SRM-36 | SRM-48 | |||||||
05 | 10 | 15 | 05 | 10 | 15 | 05 | 10 | 15 | |
Power supply | 24VDC±10% | 36VDC±10% | 48VDC±10% | ||||||
Rated current(A) | 3 | 5 | 8 | 2.5 | 5 | 8 | 2.5 | 5 | 8 |
Max. current (A) | 5 | 10 | 15 | 5 | 10 | 15 | 5 | 10 | 15 |
Continuous power(W) | 72 | 120 | 180 | 90 | 180 | 270 | 120 | 240 | 360 |
Peak output power (W) | 120 | 240 | 360 | 180 | 360 | 540 | 240 | 480 | 720 |
Speed control method | One of the following(optional): Built-in potentiometer 2.External Potentiometer 3. DC Voltage (0~5VDC) |
||||||||
Input signal | CMOS logic: H(ON): 4~5V L(OFF): 0~0.5V Start/Stop input H: start L: Stop Brake input H: instant stop L: RUN Direct of rotation H: CCW L: CW |
||||||||
Output signal | Open collector output,, External use condition 5VDC,100mA Max. Speed signal output(PG output)24P/R, Alarm signal output(ALM) |
||||||||
Protective Functions | When the following are activated, the alarm signal well be output and the motor will come to a stop: Overload protection: This will be activated when the motor load exceeds Max. current for at least 6 seconds; Over-voltage protection: This will be activated when the voltage applied to the driver exceeds power supply by at least 15%; Under-voltage protection: This will be activated when the voltage applied to the driver falls at least 25% below power supply; Out-of-phase protection: This will activated when motor signals are abnormal, due to disconnection of cable, etc. |
||||||||
Rating | continuous | ||||||||
Note | If use the brake function, the speed must be 500rpm or lower. |